Abstract

Background: Fractures of lower end radius are most common fractures of the upper extremity. Increased awareness of the complexity of the distal end radius fractures have stimulated a growing interest and promoted new ideas regarding their management. Close reduction and cast immobilization had been the mainstay of treatment of these fractures but poor functional and cosmetic results are not uncommon. The volar plate system has been shown to be reliable for the fixation of distal radius fractures. As open reduction and volar plating ensures more consistent correction of displacement and maintenance of reduction, this prospective study evaluates the anatomical and functional outcome of open reduction and plate fixation in the management of fracture distal end radius.

Method: In this study 40 patients with distal end radius fractures were included, informed consent was and clearance from ethical committee of the institute was taken. The study was Prospective, interventional and observational for the methods used for management of the fracture. Patients were evaluated pre operatively and post operatively at the end of first, fourth, sixth week,3 months and then once in 3months up to 12 months.

Results: In the prospective study conducted with forty patients,88% anatomical and 93% functional, excellent to good results suggests that stabilizing the fracture fragments with volar plate and screws in the management of the fractures of distal radius, is an effective method to maintain the reduction till union and prevent collapse of the fracture fragments, even when the fracture is grossly comminuted / intra-articular / unstable and / or the bone is osteoporotic.

Conclusion: This study concludes that open reduction and internal fixation with volar plating has excellent functional outcome with minimal complications. The procedure is applicable for all types of Frykman fractures in young patients with a good bone stock as well as in elderly osteoporotic patients.

Downloads

Download data is not yet available.

References

Colles A: On the fracture of the carpal extremity of the Radius Edinb Med Surg J 1814;10:182-186

Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Hasse SC, Kim HM. treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am, 2006 Dec;88(12):2687-94.

Leung F, Tu Y, Chew WYC, Chow SP: Comparison of External and Percutaneous Pin Fixation with Plate Fixation for Intra-articular Distal Radial Fractures. A Randomized Study. J Bone Joint Surg Am 2008;90: 16-22.

Figl M, Weninger P, Liska M, Hofbauer M, Leixnering M. Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results. Arch Orthop Trauma Surg 2009 May;129(5):661-9

Othman AY. Fixation of dorsally displaced distal radius fractures with volar plate. J Trauma. 2009 May;66(5):1416-20.

Gruber G, Zacherl M, Giessauf C, Glehr M, Fuerst F, Liebmann W, et al. Quality of life after volar plate fixation of articular fractures of the distal part of the radius. J Bone Joint Surg Am. 2010 May;92(5):1170-8.

Dillingham C, Horodyski MB, Struk AM, Wright T. Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures. Adv Orthop. 2011;2011:565642.

Lee YS, Wei TY, Cheng YC, Hsu TL, Huang CR. A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating. Int Orthop. 2012 Apr;36(4):789-94.

Gogna P, Sethi HS, Ingla R, Devgan A, Magu NK, Mahindra P, et al. Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates. ISRN Orthopedics 2013;2013, Article ID 131757, 6 pages.

Kamano M, Honda Y, Kazuki K, Yasuda M. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res. 2002 Apr;(397):403-8.

Rozental TD, Beredjiklian PK, Steinberg DR, et al. Open fractures of the distal radius. J Hand Surg [Am] 2002;27(1):77–85.

Arora R, Lutz M, Hennerbichler A, Krappinger D. Complications following internal fixation of unstable distal radius fracture with a palmar locking plate. J Orthop Trauma May 2007;21 (5) 316-22.

Prommersberger KJ, Fernandez DL. Nonunion of distal radius fractures. Clin Orthop Relat Res 2004;419:51–6.

Park MJ, Cooney WP, Hahn ME, et al. The effects of dorsally angulated distal radius fractures on carpal kinematics. J Hand Surg [Am] 2002;12(2):223–32.
Published
2017-06-30
CITATION
DOI: 10.5281/zenodo.3970548
Published: 2017-06-30
How to Cite
1.
Rassiwala M, Neema Pramod P, Sharma D K, Mishra S. Evaluation of the Results of Volar Plating in the Treatment of Fractures of Distal End Radius. ojmpc [Internet]. 2017Jun.30 [cited 2024Dec.22];23(1):4-11. Available from: https://ojmpc.com/index.php/ojmpc/article/view/43
Section
Original Article