Orthopaedic Journal of MP Chapter

Publisher: Madhya Pradesh Orthopaedic Association www.mpioa.com
E-ISSN:2582-7243, P-ISSN:2320-6993
2017 Volume 23 Number 2 Jul-Dec

A comparative study of intramedullary and extramedullary fixation devices in type two unstable trochanteric fractures

Dhakad RKS1, Jain S2*, Verma R3, Prajapati J4

1 R K S Dhakad, Department of Orthopaedics, J.A. Hospital and G.R.Medical College, Gwalior, Madhya Pradesh, India.

2* S Jain, Department of Orthopaedics, J.A. Hospital and G.R.Medical College, Gwalior, Madhya Pradesh, India.

3 R Verma, Department of Orthopaedics, J.A. Hospital and G.R.Medical College, Gwalior, Madhya Pradesh, India.

4 J Prajapati, Department of Orthopaedics, J.A. Hospital and G.R.Medical College, Gwalior, Madhya Pradesh, India.

Background: For many years, the sliding hip screw and plate had been the gold standard in treating pertrochanteric fractures. Nowadays, there is an increasing interest in intramedullary nailing. Intramedullary devices, although technically difficult seems to have a biomechanical advantage over laterally fixed side plates2.Literature is full of articles categorizing DHS in stable Trochanteric fractures, (31-A1.1, A1.2, A1.3 and 31-A2.1) and use of intramedullary devices PFN as implant of choice in unstable trochanteric, sub trochanteric fractures and particularly in reverse oblique (all A 31.3). But there is always a grey zone of decision of implant to be applied in unstable type A2.2 and A2.3 fractures. This study was designed to compare functional outcome and complications of the PFN device with those of a traditional extramedullary device, the Dynamic hip screw (DHS), inpatients with unstable type 2 trochanteric fracture. (AO/ASIF Classification 31-A2.2 & 31-A2.3)

Method: In this Randomised control prospectively, designed study 60 consecutive patients having Fracture according to AO/ASIF classification 31-A2.2 and 31-A2.3 are included and randomized to either PFN or DHS group. The functional outcome and clinical results of the patients was evaluated and graded using HARRIS HIP SCORE system.

Results: The average blood loss in PFN was 88.3ml while in DHS it was 318.33ml. Hospital stay after surgery in PFN was average days 4.13 DHS was average days 5.63. Harris hip score in PFN 22 (73.33%) were good, 06 (20%) were fair and 02 (6.66%) while with DHS 12 (40%)were good, 12(40%) were fair and 06 (20%).Average time of union in PFN was 13.4 weeks in DHS was 15.1 weeks.

Conclusion: In Type 2 unstable trochanteric fractures PFN gives advantage of lesser blood loss, shorter operating time, faster union, better functional outcome with low complication rate as compared to DHS.

Keywords: Unstable trochanteric fracture, PFN, DHS

Corresponding Author How to Cite this Article To Browse
S Jain, , Department of Orthopaedics, J.A. Hospital and G.R.Medical College, Gwalior, Madhya Pradesh, India.
Email:
Dhakad RKS, Jain S, Verma R, Prajapati J, A comparative study of intramedullary and extramedullary fixation devices in type two unstable trochanteric fractures. ojmpc. 2017;23(2):11-15.
Available From
https://ojmpc.com/index.php/ojmpc/article/view/53
Manuscript Received Review Round 1 Review Round 2 Review Round 3 Accepted
2017-12-07 2017-12-13 2017-12-19 2017-12-25 2017-12-31
Conflict of Interest Funding Ethical Approval Plagiarism X-checker Note
None Nil Yes 11.22

© 2017by Dhakad RKS, Jain S, Verma R, Prajapati Jand Published by Madhya Pradesh Orthopaedic Association. This is an Open Access article licensed under a Creative Commons Attribution 4.0 International License https://creativecommons.org/licenses/by-nc/4.0/ unported [CC BY NC 4.0].

Introduction

Unstable trochanteric fractures are a growing concern for the orthopaedic surgeons all over the world. Sliding devices like the Dynamic Hip Screw (DHS) and Intramedullary devices like the proximal femoral nail (PFN) have their own advantages & disadvantages and various meta-analysis conducted so far have come out with conflicting results regarding superiority of PFN over DHS [1].

For many years, the sliding hip screw and plate had been the gold standard in treating pertrochanteric fractures. Nowadays, there is an increasing interest in intramedullary nailing. Intramedullary devices, although technically difficult seems to have a biomechanical advantage over laterally fixed side plates [2].

Literature is full of articles categorizing DHS in stable Trochanteric fractures, (31-A1.1, A1.2, A1.3 and 31-A2.1) and use of intramedullary devices PFN as implant of choice in unstable trochanteric, subtrochanteric fractures and particularly in reverse oblique (all A 31.3) [3].

But there is always a grey zone of decision of implant to be applied in unstable type A2.2 and A2.3 fractures.  This study was designed to compare functional outcome and complications of the PFN device with those of a traditional extramedullary device, the Dynamic hip screw (DHS), inpatients with type2 trochanteric fracture. (AO/ASIF Classification 31-A2.2 & 31-A2.3)

Materials and Methods

In this prospective study from September 2014 to august 2016, 60 consecutive patients with trochanteric femoral fractures having an unstable pattern, of either sex were randomized by computer generated tables to undergo fixation with either PFN (PROXIMAL FEMORAL NAIL) or DHS (DYNAMIC HIP SCREW). A detailed history and clinical examination was done in a systemic manner and noted on a specially designed proforma. Plain radiographs were obtained on admission and all fractures categorized according to AO/ASIF classification, patients having Fracture classification 31-A2.2 and 31-A2.3 were included and randomized for the study.

Exclusion criteria -

  • AO/ASIF type other than 31-A2.2 and 31-A2.3.
  • Pathological /Compound fracture
  • Patient with other fracture in the same limb

Patients of respective groups underwent DHS or PFN using standard operating technique.

Patient were followed up fortnightly in the first month, then monthly until 6 months or till clinical and radiological union is achieved. X-ray of the involved hip with femur was done to assess union.

The functional outcome of the patients was evaluated and graded using HARRIS HIP SCORE system [4]

Harris Hip Score RESULT

90 – 100   EXCELLENT

80 – 89     GOOD

70 – 79     FAIR

o <70     POOR

Results

The following observations were made from the data collected duringthis comparative study of proximal femoral nail and dynamic hip screw in treatment of trochanteric fractures of 60 cases. 30 cases were operated for PFN and 30 cases were operated for DHS. In our study, age of patients ranged from 24 - 90 years with fracture more common in 6th decade of life. 42 (70%) patients were male and 18 (30%) were female.

In PFN group 22 (73%) patients were male and 8 (26.6%) female. In DHS group 20(66.6%) patients were male and 10 (33.3%) female. Out of 60 patients, 37 (61.6%) have AO Type Fracture 31-A2.2 and 23 (38.3%) patients have AO Type Fracture 31-A2.3. X2 = 0.2, OR=0.65 (0.23-1.86)

Table No. 1: AO Type Fracture

TypePFNDHSTotal
31.A2.217
56.6%)
20
(63.4%)
37
(61.6%)
31.A2.313 (43.3%)10 (33.3%)23 (38.3%)

The average time for PFN surgery was 44.83 minutes, standard deviation (SD) = ± 4.83 and average time for DHS surgery was 60.16 minutes, standard deviation (SD) = ± 5.16 Student- t Test T=11.88 p value =<0.05 (Highly significant).

The average blood loss in PFN was 88.3ml, standard deviation (SD) = ± 12.88 and average blood loss in DHS was 318.33ml, standard deviation (SD) = ± 24.50, Student-t-Test T=45.22 p value =<0.05 (Highly significant).

Hospital stay after surgery in PFN was average days 4.13 AND in DHS was days 5.63 standard deviation (SD)= +0.49 p value =<0.05 (Highly significant)

Table No. 2: Harris Hip Score

Score of PatientsPFNDHS
Good(80-89)22 (73.33%)12 (40%)
Fair (70-79)06 (20%)12(40%)
Poor (<70)02 (6.66%)06 (20%)

x2=6.94  p value = 0.03( <0.05 significant)

Table No. 3: Intra Operative complication PFN

ComplicationNo.%
1. Failure to achieve closed reduction013.3%
2. Fracture of Lateral Cortex0310%
3. Varus Malrotation026.6%
4. Fracture displacement by Nail insertion013.3%

Table No. 4: Intra Operative complication DHS

ComplicationNo.%
1. Improper insertion of compression screw026.6%
2. Medial Displacement of Distal fragment0413.3%

Table No. 5: Infection

No. of PatientsPFNDHS
Infection01(3.03%)02(6.66%)
Normal29(96.7%)28(93.33%)

x2=0.87  OR(95%CI)=0.22 (0.02=2.14)

Table No. 6: Implant Failure

ImplantNo. Of PatientsPercentage
PFN00
DHS13.3%

Average time to union in PFN was 13.4 weeks standard deviation (SD) ±1.19 ,and average time to union in DHS was 15.1 weeks standard deviation ± 0.93, p value= 0.000001( significant)

Discussion

Fractures of intertrochanteric femur have been recognized as a major challenge by the Orthopaedic community, not solely for achieving fractures union, but for restoration of optimal function in the shortest possible time that to with minimal complications. The aim of management accordingly has drifted to achieving early mobilization, rapid rehabilitation and quick return of individuals to pre-injury state. Operative treatment in the form of internal fixation permits early rehabilitation and offers the best chance of functional recovery, and hence has become the treatment of choice for virtually allfractures in the trochanteric region. Literature so far does not support any treatment DHS or PFN as an exclusive option for unstable type II fracture.

In this study an attempt was made to evaluate our success in the management of such individuals by using Proximal femoral nail (PFN) and Dynamic Hip Screw (DHS) implants and compare the result in these two groups.

  Ujjal Bhakat et al in his study on 60 patients, reported average operating time for the patients treated with PFN - 45 min as compared to 70 min in patients treated with DHS [5]. In 2016, Neritan Myderrizi, conducted study on 63 patients, average operating time for the patients treated with PFN was 49.3 min as compared to 72.3 min in patients treated with DHS [6]. Ujjal Bhakat reported average blood loss 100 ml in PFN surgery and 250 ml in DHS surgery. This study shows similar results for duration of surgery and blood loss.

In 2011 Richard Armelin Borger, conducted study on 70 patients of trochantric fracture. 40 patients underwent osteosynthesis by PFN with unstable trochantric fracture. The Harris Hip score one year after the operation in 16% of the patients was excellent, 19% good, 28% reasonable and 38% poor [7]. In 2015, S.K. Venkatesh Gupta, Conducted study on 400 patients in group 1 (240 patients treated with DHS) excellent result was observed in 37.5 %contrast to 66.2% in group 2 (160 patients treated with PFN). In this study functional outcome was better in PFN group (good result in 73.3 % in PFN Vs 40% in DHS group) [8]. Umesh M. Shivanna, conducted study on 30 patients of trochanteric fracture. All the fractured united at a mean of 12 weeks [9].

In 2015, Hemant Sharma reported no significant difference in time to union between the two groups (mean 16.71 vs. 17.27 weeks) P > 0.05 [10]. In our study average time to union in PFN group was 13.4 weeks as compared to 15.1 weeks in DHS group, this difference was statistically significant (p value= 0.000001).

Conclusion

In Type 2 unstable trochanteric fractures PFN gives advantage of lesser blood loss, shorter operating time, faster union, better functional outcome with low complication rate as compared to DHS.

References

1. Huang, Xiao et al. “Proximal Femoral Nail versus Dynamic Hip Screw Fixation for Trochanteric Fractures: A Meta-Analysis of Randomized Controlled Trials. ” The Scientific World Journal 2013 (2013): 805805. PMC. Web. 19 Nov. 2017 [Crossref][PubMed][Google Scholar]

2. Curtis, M. J. & Jinnah, R. H. & Wilson, V & Cunningham, B.W.. (1994). Proximal femoral fractures: a biomechanical study to compare intramedullary and extramedullary fixation. Injury. 25. 99-104. 10.1016/0020-1383(94)90111-2 [Crossref][PubMed][Google Scholar]

3. Orthopaedic Trauma Association Classification, Database and Outcomes Committee. Fracture and dislocation classification compendium - 2007. J Orthop Trauma 2007; 10 Suppl. ). [Crossref][PubMed][Google Scholar]

4. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 1969; 51:737–55. [Crossref][PubMed][Google Scholar]

5. Ujjal Bhakat, Ranadeb Bandyopadhayay. Comparitive Study between Proximal Femoral Nailing and Dynamic Hip Screwin Intertrochanteric Fracture of Femur. Open Journal of Orthopedics. 22013, 3, 291-295. [Crossref][PubMed][Google Scholar]

6. Neritan Myderrizi, Proximal femoral nailing is better choice in treatment of intertrochanteric fracture in elderly people. International Surgery Journal Myderrizi N. Int Surg J. 2016 May;3(2):781-785. [Crossref][PubMed][Google Scholar]

7. Richard Armelin Borger, “prospective assessment of the clinical, radiographic and functional evolution of treatment for unstable. Trochanteric fractures of the femur using a cephalomedullary nail”, Revista Brasileira de Ortopedia Rev. bras. ortop. vol.46 no.4 São Paulo 2011 Print version ISSN 0102-3616 [Crossref][PubMed][Google Scholar]

8. S. K. Venkatesh Gupta, Veera Shekar Valisetti,Comparative study between dynamic hip screw vs proximal femoral nailing in inter-trochanteric fractures of the femur in adults, International Journal of Orthopaedics Sciences 2015; 1(1): 07-11. ISSN: 2395-1958IJOS 2015;. [Crossref][PubMed][Google Scholar]


9. Umesh M. Shivanna, Girish H. Rudrappa. “A Comparative Study of Functional Outcome between Dynamic Hip Screw and Proximal Femoral Nail in Surgical Management of Per-Trochanteric Fractures”. Journal of Evolution of Medical and Dental Sciences 2015; Vol. 4, Issue 43, May 28; Page: 7489-7498, [Crossref][PubMed][Google Scholar]

10. Hemant Sharma, Deepinder Singh Loomba,Comparison of outcome of management of unstable pertrochanteric femoral fractures with dynamic hip screw and proximal femoral nail,African Journal of Trauma |Jan-Jun-2015|Vol. 4| Issue 1,DOI:10. 4103/1597-1112. 162236. [Crossref][PubMed][Google Scholar]

Disclaimer / Publisher's Note

The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of Journals and/or the editor(s). Journals and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.